Equal Elbow Brass Compression Fitting For Al-pex Pipe
Optional Specification
Product Information
Product name | Brass Equal Elbow Al-Pex Fittings | |
Sizes | 16, 20, 26, 32 | |
Bore | Standard bore | |
Application | Water, oil, gas, and other non-corrosive liquid | |
Working pressure | PN16 / 200Psi | |
Working temperature | -20 to 120°C | |
Working durability | 10,000 cycles | |
Quality standard | ISO9001 | |
End Connection | BSP, NPT | |
Features: | Forged brass body | |
Precise dimensions | ||
Various sizes available | ||
OEM production acceptable | ||
Materials | Spare Part | Material |
Body | Forged brass, sandblasted and nickel-plated | |
Nut | Forged brass, sandblasted and nickel-plated | |
Insert | Brass | |
Seat | Open copper ring | |
Seal | O-ring | |
Stem | N/A | |
Screw | N/A | |
Packing | Inner boxes in cartons, loaded in pallets | |
Customized design acceptable |
Key Words
Brass Fittings, Brass Aluminum Pex pipe Fittings, Water Pipe Fittings, Tube Fittings, Brass Pipe Fittings, Plumbing Fittings, Al-Pex Pipe Fittings, Elbow Al-Pex Fittings, Compression Fitting, Brass Pipe Fittings, Brass Elbow Al-Pex Fittings, Brass Compression Fittings, Brass Elbow Pipe Fittings, Female Elbow Al-Pex Fittings, Plumbing Pipe Fittings, Pex Push Fittings,Brass Elbow Pex Fittings, Brass Pex Fittings Elbow
Optional Materials
Brass CW617N, CW614N, HPb57-3, H59-1, C37700, DZR, Lead-free
Applications
Fluid control system for building and plumbing: Water,oil, Gas, and other non-corrosive liquid
Brass Pex fittings is made of forged brass or machined from brass bar, designed to connect Pex pipes and other pipeline applications.Peifeng is a professional China brass fittings manufacturer and supplier.
Inspection of Brass Compression Fittings After Installation:
If the brass compression joint is not screwed in place, it may leak (it may not leak at the time, but it will become a hidden danger after operation). Site managers can check in three ways:
(1) Check the mark on the compression joint to see if it has been screwed 1-1/4 turns (or 3/4 turns);
(2) Disassemble the compression joint to see if the compression is firmly stuck on the TUBE pipe;
(3) Use a gap inspection gauge for inspection.
Method 1: It is simple and easy to implement, and it can be carried out before and after the pipeline is ventilated or watered. Let the workers install several crimping joints in strict accordance with the steps, and they all meet the requirements after testing with a gap inspection gauge.
Method 2: It is only applicable to spot checks before pipeline ventilation or water supply.
Method 3: It is also very simple. If the inspection gauge cannot be inserted into the gap, it means that the joint has been fully tightened. If the gap can be inserted, tightening is also required. Gap inspection gauges can be supplied by the supplier or purchased separately. However, it should be noted that the "gap" after tightening the brass press fittings of different brands may be different. Therefore, it is recommended that the press fittings of different brands should be checked with the test gauge of the same brand.